| Technology | Temperature measurement |
| Sensor types | thermocouples type K, J, L, E, T, N, U, B, R, S, C (default: type K) |
| Number of inputs | 4 (differential) |
| Connection method | 2-wire |
| Measuring range | depending on sensor type, type K -270…+1370°C, voltage measurement: ±30…±75 mV, for further types and details see documentation |
| Resolution | 0.1В°C per digit |
| Measurement error/uncertainty | |
| Internal resistance | typ. ≥ 10 kΩ (differential) |
| Input filter limit frequency | typ. 1 kHz, depending on sensor length, conversion time, sensor type |
| Conversion time | 10…5000 ms (adjustable, default: 310 ms) |
| Supply voltage electronics | 24 V DC (via power contacts), ELX9560 power supply |
| Current consumption power contacts | typ. 10 mA |
| Current consumption E-bus | typ. 70 mA |
| Special features | limit value monitoring, digital filter and characteristic curve linearization integrated |
| Weight | approx. 60 g |
| Operating/storage temperature | -25…+60°C/-40…+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/see documentation |
| Approvals/markings | CE, UL, ATEX, IECEx, cFMus, CCC |
| Ex marking | ATEX: В В II 3(1)G Ex ec [ia Ga] IIC T4 Gc В В II (1)D [Ex ia Da] IIIC В В I (M1) [Ex ia Ma] I IECEx: В В Ex ec [ia Ga] IIC T4 Gc В В [Ex ia Da] IIIC В В [Ex ia Ma] I cFMus: В В AIS Class I, II, III, Division 1, Groups A thru G В В Class I, Division 2, Groups A, B, C, D В Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc В В [AEx ia Da] IIIC T4 |