| Connection technology | pulse train (frequency output) |
| Number of outputs | 2 channel A/B, 1 channel A/B/C (4 differential outputs) |
| Distributed clocks | yes |
| Output specification | RS422, differential, 50 mA, min. 120 О© load |
| Short-circuit current | short-circuit proof |
| Base frequency | 0…4 MHz, 50 kHz default |
| Resolution | 16 bit (incl. sign, scaled via the set frequency range) |
| Current consumption E-bus | typ. 120 mA |
| Power supply | via the E-bus |
| Electrical isolation | 500 V (E-bus/field potential) |
| Current consumption power contacts | typ. 50 mA (load-dependent) |
| Special features | pulse output with variable frequency: frequency modulation, pulse direction specification, 1 x ABC or 2 x AB incremental encoder simulation with connection to TwinCAT NC, ramp function, travel distance control |
| Weight | approx. 50 g |
| Operating/storage temperature | -25…+60°C/-40…+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/variable |
| Approvals/markings | CE, UL |