Additional Features:

  • Constant Voltage/Constant Current
  • Built-in RS-232 & RS-485 Interface
  • An embedded Microprocessor controller
  • Digital Encoder Knob
  • Software Calibration
  • Last Setting Memory
  • Parallel Operation (Master/Slave) Active Current Sharing
  • External Voltage or Resistance Programming
  • Active Power Factor Correction: 99%
  • 85~265Vac Universal Input Voltage
  • 19″ Rack Mounted ATE and OEM
  • Worldwide Safety Agency Approvals
  • CE Mark for LVD and EMC Regulation

Applications

  • Industrial
  • Test

Specifications:

  • Output Voltage Range: 0-36 V
  • Output Current Range: 0-24 A
  • Maximum Power: 864 W
  • Ripple 5 Hz-1 MHz: 5 mV
  • Noise 20 MHz BW: 70 mV
  • Ripple 5 Hz-1 MHz: 30 mA
  • Efficiency (100/200 VAC): 80/84 %
  • Load Regulation: 2mV + 0.005% over 0 – 100% load change
  • Line Regulation: 1mV + 0.005% over 85 – 132 or 170 – 265VAC line change
  • Recovery Time: 0.2ms
  • Temperature Coefficient: 30ppm/°C following 30 minute warm up
  • Temperature Drift: 0.01% + 2mV change in output
  • Up programming response time: 50 – 60ms
  • Down programming response time (CV): 50ms
  • Load Regulation: 0.07% + 10mA on 800W models
  • Line Regulation: 0.01% + 5mA on 800W models
  • Temperature Coefficient: 100ppm/°C from rated current after 30 minute warm up time
  • Temperature Drift: 0.05% + 10mA 800W models
  • Prog Voltage resolution: Better than 0.028% of rated voltage
  • Prog Voltage accuracy: .02%+20mV
  • Prog Current resolution: Better than 0.03% of rated output current
  • Prog Current accuracy: 0.4% + 40mA
  • Overvoltage Shutdown: 0-40
  • Thermal Protection: Over temperature protected
  • Display – Voltage: 3 digits
  • Display – Status: CV / CC, Alarm, Foldback, Local/Remote, On/Off
  • Remote On/Off: TTL signal or dry contact relay
  • Output Good: Open Collector
  • Voltage & Current Programming: By either Voltage (0-4V) or Resistance (0-4k)
  • Remote Sense: Up to 0.5V compensation per output cable
  • Communication Interface: RS232 & RS485 standard, IEEE488 optional
  • Series & Parallel Operation: Series: Up to two units, Parallel: Up to five units in master-slave configuration
  • AC Input Voltage range: 85-265VAC (47-63Hz)
  • Inrush Current (100/200VAC): 30A
  • Hold Up Time (Typ) at 100VAC: 20 ms
  • Power Factor Correction: Complies with EN61000-3 Class A (0.99 typ)
  • Temperature Range: Operating: 0 – 50°C, Storage: -20 to +70°C
  • Humidity (non condensing): Operating: 30 – 90% RH, Storage 10 – 95%RH
  • Cooling: Internal fan
  • Withstand Voltage: Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min
  • Isolation Resistance: &gt,100M at 25°C & 70% RH
  • Vibration & Shock (non-op.): Vibration:10-55 Hz(1 min.) 2G constant X, Y, Z, when correctly mounted, Shock: &lt,20G
  • Safety Agency Approvals: UL3111-1, EN61010-1, CE Mark
  • Conducted & Radiated EMI: EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated

The TDK Lambda ZUP36-24 is a 0-36 V, 0-24 A Zero up programmable DC Power Supply with an output power of 864 Watts. The ZUP36-24 is perfect for Industrial and Test applications.

Технические характеристики

Manufacturer Lambda
Condition Used
Current 24 A
Voltage 36 V
Power 864 W
+79043698209