| Technology | incremental encoder interface, differential (RS422) |
| Number of channels | 1 |
| Encoder connection | 1 x A, B, C: differential inputs (RS422): A, AМ… (inv), B, BМ… (inv), C,CМ… (inv) |
| Encoder operating voltage | 5 V DC/max. 0.5 A (generated from the 24В VВ DC power contacts) |
| Counter | 1 x 32 bit |
| Limit frequency | 20 million increments/s (with 4-fold evaluation), corresponding to 5 MHz |
| Quadrature decoder | 4-fold evaluation |
| Distributed clocks | yes |
| Oversampling factor | n = 1…100 selectable |
| Cycle time | min. 500 Вµs |
| Conversion time | 10 Вµs/100 ksps |
| Current consumption power contacts | typ. 100 mA + load |
| Current consumption E-bus | typ. 130 mA |
| Electrical isolation | 500 V (E-bus/field potential) |
| Special features | oversampling, wire breakage detection, set counter |
| Weight | approx. 100 g |
| Operating/storage temperature | -25…+60°C/-40…+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/variable |
| Approvals/markings | CE, UL, ATEX, IECEx |
| Ex marking | ATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc |