EJ3048 | EtherCAT plug-in module, 8-channel analog input, current, 0…20 mA, 12 bit, single-ended
0,00 ₽The EJ3048 EtherCAT plug-in module processes signals in the range between 0 and 20В mA. The current is digitized to a resolution of 12В bit, and is transmitted, electrically isolated, to the higher-level automation device. The module combines eight channels in one housing. The signal state is indicated by light emitting diodes.
-
EJ3058 | EtherCAT plug-in module, 8-channel analog input, current, 4…20 mA, 12 bit, single-ended
0,00 ₽Подключаемый модуль EJ3058 EtherCAT обрабатывает сигналы в диапазоне от 4 до 20 В мА. Ток оцифровывается до разрешения 12 В бит и передается в электрически изолированном виде на устройство автоматизации более высокого уровня. Модуль объединяет восемь каналов в одном корпусе. Состояние сигнала индицируется светодиодами.
-
EJ3108 | EtherCAT plug-in module, 8-channel analog input, voltage, В±10В V, 16В bit
0,00 ₽The EJ3108 EtherCAT plug-in module processes signals in the range between -10 and +10В V. The voltage is digitized to a resolution of 16В bits, and is transmitted, electrically isolated, to the higher-level automation device. Of the eight input channels, six are designed as differential and two as single-ended inputs. The signal state is indicated by light emitting diodes.
-
EJ3314-0090 | EtherCAT plug-in module, 4-channel analog input, temperature, thermocouple, 16В bit, TwinSAFE SC
0,00 ₽The EJ3314-0090 EtherCAT plug-in module allows four thermocouples to be connected directly. The module circuit can operate thermocouple sensors using the 2-wire technique. A microprocessor handles linearization across the whole temperature range, which is freely selectable. Compensation for the cold junction is made through an internal temperature measurement at the module. The EJ3314-0090 can also be used for mV measurement.
-
EJ3318 | EtherCAT plug-in module, 8-channel analog input, temperature, thermocouple, 16В bit
0,00 ₽The EJ3318 EtherCAT plug-in module allows the direct connection of eight thermocouples and is therefore particularly well suited to compact applications on the signal distribution board. The module’s circuit can operate thermocouple sensors using the 2-wire technique. A microprocessor handles linearization across the whole temperature range, which is freely selectable. The error LEDs indicate a broken wire. The compensation for the cold junction is done by two RTDs (Pt1000), which can be placed anywhere on the signal distribution board. The EJ3318 can also be used for mV measurements.